How to prevent your sprinkler system from freezing

How to prevent a sprinkler system from freezing? Identify/correct installation and design defects to avoid costly repairs.

Share this post

Installation of a Dry Sprinkler
Dry sprinklers are so named because there isn’t any water in the pipe barrel until the system needs to operate. Instead, the dry pipe sprinkler features a barrel with a seal at the connection point to the wet pipe sprinkler system. Water does not enter the barrel until the sprinkler operates which releases the seal. This keeps the part exposed to the freezing conditions dry and unable to freeze. Although this process is nothing new, we are discovering that some installations do not meet the minimum code requirements or manufacturer’s installation guidelines.

With dry type sprinklers, there are two main concerns with installation. The first area of concern is the length of the barrel and the second is the distance between the face of the fitting and the inside surface of the exterior wall or insulation, whichever is closer to the fitting.

Fire Sprinkler Pipe Insulation Matters
The second means of preventing a wet pipe sprinkler system from freezing is by insulating the sprinkler pipe. Using insulation over the sprinkler pipe traps the flow of warm from the adjacent spaces.

When the proposed sprinkler insulation installation method is not one of those prescribed by the NFPA, heat loss calculations are required to be performed by a professional engineer to verify that the system will not freeze.

There are nine different NFPA prescribed approaches dealing with sprinkler system freeze protection. Although the requirements for preventing a sprinkler system from freezing are clear, some designs and installations are overlooked, and you could end footing a repair bill that could be avoided. Identifying and correcting deficiencies prior to the completion of construction can potentially save you thousands of dollars in future repairs.

What’s been your experience with wet pipe fire sprinkler systems? Shoot us a note at info@jensenhughes.com or tweet us @jensenhughes

Comments

More blog posts from Jensen Hughes


The Russia-Ukraine War Has Clear Cyber Security Implications for Your Organization

Mar 10, 2022

The Russian invasion of Ukraine has escalated the threat of Russian state-sponsored cybercrime worldwide.

Read more
World Engineering Day + Nuclear Safety: The Future of Nuclear Safety

Mar 4, 2022

Marlene Delaney addresses the common misconceptions about nuclear power and discusses the future of nuclear technology.

Read more
Fire Risk Assessments As PART OF A preventative strategy

Feb 23, 2022

Learn how Fire Risk Assessments can help building managers effectively identify fire safety risks within their building.

Read more